Immersion sensor with housing, without well

Immersion sensor for temperature measurement in heating- or cooling applications. Available in different lengths. The sensor needs to be installed in a well.

Articles

(9 st)
  • TG-IH3/NI1000-01-90 - Regin
    TG-IH3/NI1000-01-90
    Dimensions, external (WxHxD)
    78*156*104 mm
    Media Temp Limits
    -20…120 °C
    Insertion length
    90… mm
    Time constant
    18 s
    Diameter
    5
    Element type
    NTC10-01
    Measuring range, Temp
    -20…120 °C
    Nominal resistance
    1000 Ω (0°C)
  • TG-IH3/NTC20-90 - Regin
    TG-IH3/NTC20-90
    Dimensions, external (WxHxD)
    78*156*104 mm
    Media Temp Limits
    -20…120 °C
    Insertion length
    90… mm
    Time constant
    18 s
    Diameter
    5
    Element type
    NTC20
    Measuring range, Temp
    -20…120 °C
    Nominal resistance
    20 kΩ (25 °C)
  • TG-IH3/PT1000-120 - Regin
    TG-IH3/PT1000-120
    Dimensions, external (WxHxD)
    78*156*104 mm
    Media Temp Limits
    -20…120 °C
    Insertion length
    120… mm
    Time constant
    18 s
    Diameter
    5
    Element type
    Pt1000
    Measuring range, Temp
    -20…120 °C
    Sensor element, Class
    DIN Class B: ±(0.3 + .005 |T|°C)
    Nominal resistance
    1000 Ω (0°C)
  • TG-IH3/PT1000-170 - Regin
    TG-IH3/PT1000-170
    Dimensions, external (WxHxD)
    78*156*104 mm
    Media Temp Limits
    -20…120 °C
    Insertion length
    170… mm
    Time constant
    18 s
    Diameter
    5
    Element type
    Pt1000
    Measuring range, Temp
    -20…120 °C
    Sensor element, Class
    DIN Class B: ±(0.3 + .005 |T|°C)
    Nominal resistance
    1000 Ω (0°C)
  • TG-IH3/PT1000-310 - Regin
    TG-IH3/PT1000-310
    Dimensions, external (WxHxD)
    78*156*104 mm
    Media Temp Limits
    -20…120 °C
    Insertion length
    310… mm
    Time constant
    18 s
    Diameter
    5
    Element type
    Pt1000
    Measuring range, Temp
    -20…120 °C
    Sensor element, Class
    DIN Class B: ±(0.3 + .005 |T|°C)
    Nominal resistance
    1000 Ω (0°C)
  • TG-IH3/PT1000-50 - Regin
    TG-IH3/PT1000-50
    Dimensions, external (WxHxD)
    78*156*104 mm
    Media Temp Limits
    -20…120 °C
    Insertion length
    50… mm
    Time constant
    18 s
    Diameter
    5
    Element type
    Pt1000
    Measuring range, Temp
    -20…120 °C
    Sensor element, Class
    DIN Class B: ±(0.3 + .005 |T|°C)
    Nominal resistance
    1000 Ω (0°C)
  • TG-IH3/PT1000-90 - Regin
    TG-IH3/PT1000-90
    Dimensions, external (WxHxD)
    78*156*104 mm
    Media Temp Limits
    -20…120 °C
    Insertion length
    90… mm
    Time constant
    18 s
    Diameter
    5
    Element type
    Pt1000
    Measuring range, Temp
    -20…120 °C
    Sensor element, Class
    DIN Class B: ±(0.3 + .005 |T|°C)
    Nominal resistance
    1000 Ω (0°C)
  • TG-IH3/PT100-90 - Regin
    TG-IH3/PT100-90
    Dimensions, external (WxHxD)
    78*156*104 mm
    Media Temp Limits
    -20…120 °C
    Insertion length
    90… mm
    Time constant
    18 s
    Diameter
    5
    Element type
    PT100
    Measuring range, Temp
    -20…120 °C
    Sensor element, Class
    DIN Class B: ±(0.3 + .005 |T|°C)
    Nominal resistance
    100 Ω (0°C)
  • TG-IH3/NTC10-01-90 - Regin
    TG-IH3/NTC10-01-90
    Dimensions, external (WxHxD)
    78*156*104 mm
    Media Temp Limits
    -20…120 °C
    Insertion length
    90… mm
    Time constant
    18 s
    Diameter
    5
    Element type
    NTC10-01
    Measuring range, Temp
    -20…120 °C
    Nominal resistance
    10 kΩ (25°C)
Specifications for Immersion sensor with housing, without well
Protection class IP65
Cable gland M16x1,5
Terminal Type Screw Terminal
Deteachable Terminal True
Terminal wire size 1.5 mm²
Material, housing Polycarbonate (PC)
Material, cover Polycarbonate (PC)
Material sensor EU1.4301 (SUS304)
DR-50WA

Well in acid-proof stainless steel, for TG-IH3.

DR-90WA

Well in acid-proof stainless steel, for TG-IH3.

DR-120WA

Well in acid-proof stainless steel, for TG-IH3.

DR-170WA

Well in acid-proof stainless steel, for TG-IH3.

DR-310WA

Well in acid-proof stainless steel, for TG-IH3. Available upon request, please contact Regin for more information.

DR-120S

Well in stainless steel, for TG-IH3.

DR-170S

Well in stainless steel, for TG-IH3.

DR-310S

Well in stainless steel, for TG-IH3.

DR-50S

Well in stainless steel, for TG-IH3.

DR-90S

Well in stainless steel, for TG-IH3.

TG-DHW3-CLIP