GF - 2- and 3-way control valves, DN25-200, kvs 6.3-550, DIN-standard
Control valves for use in heating, cooling and ventilation systems. They are intended to be used together with Regin’s RVAN actuators. The valves have DIN-standard lengths.
Navigate on this page
Articles
(34 st)-
GF225-6.3
- Nominal diameter
- DN25
- Kvs
- 6.3 m 3 /h
- Max. diff. pressure
- 400 kPa
- Actuator
- RVAN5, RVAN10
-
GF325-10
- Nominal diameter
- DN25
- Kvs
- 10 m 3 /h
- Max. diff. pressure
- 400 kPa
- Actuator
- RVAN5, RVAN10
-
GF225-10
- Nominal diameter
- DN25
- Kvs
- 10 m 3 /h
- Max. diff. pressure
- 400 kPa
- Actuator
- RVAN5, RVAN10
-
GF232-10
- Nominal diameter
- DN32
- Kvs
- 10 m 3 /h
- Max. diff. pressure
- 350 kPa
- Actuator
- RVAN5, RVAN10
-
GF232-16
- Nominal diameter
- DN32
- Kvs
- 16 m 3 /h
- Max. diff. pressure
- 350 kPa
- Actuator
- RVAN5, RVAN10
-
GF240-16
- Nominal diameter
- DN40
- Kvs
- 16 m 3 /h
- Max. diff. pressure
- 300 kPa
- Actuator
- RVAN5, RVAN10
-
GF240-25
- Nominal diameter
- DN40
- Kvs
- 25 m 3 /h
- Max. diff. pressure
- 300 kPa
- Actuator
- RVAN5, RVAN10
-
GF250-31.5
- Nominal diameter
- DN50
- Kvs
- 31.5 m 3 /h
- Max. diff. pressure
- 450 kPa
- Actuator
- RVAN18
-
GF250-40
- Nominal diameter
- DN50
- Kvs
- 40 m 3 /h
- Max. diff. pressure
- 450 kPa
- Actuator
- RVAN18
-
GF265-50
- Nominal diameter
- DN65
- Kvs
- 50 m 3 /h
- Max. diff. pressure
- 350 kPa
- Actuator
- RVAN18
-
GF265-63
- Nominal diameter
- DN65
- Kvs
- 63 m 3 /h
- Max. diff. pressure
- 350 kPa
- Actuator
- RVAN18
-
GF280-80
- Nominal diameter
- DN80
- Kvs
- 80 m 3 /h
- Max. diff. pressure
- 300 kPa
- Actuator
- RVAN18
-
GF280-100
- Nominal diameter
- DN80
- Kvs
- 100 m 3 /h
- Max. diff. pressure
- 300 kPa
- Actuator
- RVAN18
-
GF2100-125
- Nominal diameter
- DN100
- Kvs
- 125 m 3 /h
- Max. diff. pressure
- 200 kPa
- Actuator
- RVAN18
-
GF2100-160
- Nominal diameter
- DN100
- Kvs
- 160 m 3 /h
- Max. diff. pressure
- 200 kPa
- Actuator
- RVAN18
-
GF2125-215
- Nominal diameter
- DN125
- Kvs
- 215 m 3 /h
- Max. diff. pressure
- 120 kPa
- Actuator
- RVAN25
-
GF2150-310
- Nominal diameter
- DN150
- Kvs
- 310 m 3 /h
- Max. diff. pressure
- 100 kPa
- Actuator
- RVAN25
-
GF2200-550
- Nominal diameter
- DN200
- Kvs
- 550 m 3 /h
- Max. diff. pressure
- 200 kPa
- Actuator
- RVAN25
-
GF325-6.3
- Nominal diameter
- DN25
- Kvs
- 6.3 m 3 /h
- Max. diff. pressure
- 400 kPa
- Actuator
- RVAN5, RVAN10
-
GF332-10
- Nominal diameter
- DN32
- Kvs
- 10 m 3 /h
- Max. diff. pressure
- 350 kPa
- Actuator
- RVAN5, RVAN10
-
GF332-16
- Nominal diameter
- DN32
- Kvs
- 16 m 3 /h
- Max. diff. pressure
- 350 kPa
- Actuator
- RVAN5, RVAN10
-
GF340-16
- Nominal diameter
- DN40
- Kvs
- 16 m 3 /h
- Max. diff. pressure
- 300 kPa
- Actuator
- RVAN5, RVAN10
-
GF340-25
- Nominal diameter
- DN40
- Kvs
- 25 m 3 /h
- Max. diff. pressure
- 300 kPa
- Actuator
- RVAN5, RVAN10
-
GF350-31.5
- Nominal diameter
- DN50
- Kvs
- 31.5 m 3 /h
- Max. diff. pressure
- 450 kPa
- Actuator
- RVAN18
-
GF350-40
- Nominal diameter
- DN50
- Kvs
- 40 m 3 /h
- Max. diff. pressure
- 450 kPa
- Actuator
- RVAN18
-
GF365-50
- Nominal diameter
- DN65
- Kvs
- 50 m 3 /h
- Max. diff. pressure
- 350 kPa
- Actuator
- RVAN18
-
GF365-63
- Nominal diameter
- DN65
- Kvs
- 63 m 3 /h
- Max. diff. pressure
- 350 kPa
- Actuator
- RVAN18
-
GF380-80
- Nominal diameter
- DN80
- Kvs
- 80 m 3 /h
- Max. diff. pressure
- 300 kPa
- Actuator
- RVAN18
-
GF380-100
- Nominal diameter
- DN80
- Kvs
- 100 m 3 /h
- Max. diff. pressure
- 300 kPa
- Actuator
- RVAN18
-
GF3100-125
- Nominal diameter
- DN100
- Kvs
- 125 m 3 /h
- Max. diff. pressure
- 200 kPa
- Actuator
- RVAN18
-
GF3100-160
- Nominal diameter
- DN100
- Kvs
- 160 m 3 /h
- Max. diff. pressure
- 200 kPa
- Actuator
- RVAN18
-
GF3125-215
- Nominal diameter
- DN125
- Kvs
- 215 m 3 /h
- Max. diff. pressure
- 120 kPa
- Actuator
- RVAN25
-
GF3150-310
- Nominal diameter
- DN150
- Kvs
- 310 m 3 /h
- Max. diff. pressure
- 100 kPa
- Actuator
- RVAN25
-
GF3200-550
- Nominal diameter
- DN200
- Kvs
- 550 m 3 /h
- Max. diff. pressure
- 70 kPa
- Actuator
- RVAN25
Specifications
Application | Heating systems, cooling systems, ventilation systems |
---|---|
Pressure rating | PN16 |
Connection | Flanged according to EN 1092-2 |
Flow characteristics | A - AB = equal percentage, B - AB = linear |
Max. leakage | 0 % of Kvs |
Media | Hot water, cold water, glycol-mixed water |
Media temperature | -5…+120°C |
Rangeability | 100:1 (DN50…200), > 50:1 (DN25…40) |
Max. diff. pressure | If a smaller actuator than the suggested one is used, the max. differential pressure may be different. More information is available in the product sheet. |
Body | Grey cast iron EN-JL1040/EN-GJL-250 |
Plug | Gunmetal 1400 LG2 (DN50…200), Brass CW614N (DN25…40) |
Seat | Gunmetal 1400 LG2 (DN50…200), Cast iron Grade 250 (DN25…40) |
Stem | Stainless steel 1.4305 |
Packing box | Brass CW614N |
Bonnet | Brass CW614N |
O-rings | EPDM |
Packing | Aramid reinforced rubber |
Software & documentation
Accessories

S2921354201
Spare parts kit, packing box, for BTV (from 2019-01), GF (DN25-40), BF

S2921351201
Spare parts kit, packing box DN50-200

STEMHEATER
Valve stem heater

02133005
Washer for actuator, 3 mm thick with ø14 mm hole. For RVAN5 and RVAN10 on DN50-65 GF-valves.