Regio Mini – Pre-programmed room controllers without communication
Stand-alone controllers for control of heating and cooling in a single zone or room
The Regio Mini controllers can be configured for a specific application via the display or dipswitches (in most cases, though, the default settings can be applied). The controllers have a built-in temperature sensor. Alternatively, an external temperature sensor can be connected.
RC is the basic model in the range. The other models have various functions, indicated by the letters in the product name:
D = Display, F = Fan control (3-speed), H = Hidden setpoint, O = Occupancy button, T = 3-point output
The Regio Mini controllers can be configured for a specific application via the display or dipswitches (in most cases, though, the default settings can be applied). The controllers have a built-in temperature sensor. Alternatively, an external temperature sensor can be connected.
RC is the basic model in the range. The other models have various functions, indicated by the letters in the product name:
D = Display, F = Fan control (3-speed), H = Hidden setpoint, O = Occupancy button, T = 3-point output
Navigate on this page
Articles
(8 st)-
RC
- Occupancy button / Forced ventilation
- -
- 3-step fan control
- -
- Setpoint knob
- X
- Hidden setpoint
- -
- Output
- 0...10 V DC or on/off
- Display
- -
-
RC-O
- Occupancy button / Forced ventilation
- X
- 3-step fan control
- -
- Setpoint knob
- X
- Hidden setpoint
- -
- Output
- 0...10 V DC or on/off
- Display
- -
-
RC-H
- Occupancy button / Forced ventilation
- -
- 3-step fan control
- -
- Setpoint knob
- -
- Hidden setpoint
- X
- Output
- 0...10 V DC or on/off
- Display
- -
-
RC-DO
- Occupancy button / Forced ventilation
- X
- 3-step fan control
- -
- Setpoint knob
- -
- Hidden setpoint
- -
- Output
- 0...10 V DC or on/off
- Display
- X
-
RC-DFO
- Occupancy button / Forced ventilation
- X
- 3-step fan control
- X
- Setpoint knob
- -
- Hidden setpoint
- -
- Output
- 0...10 V DC or on/off
- Display
- X
-
RC-T
- Occupancy button / Forced ventilation
- -
- 3-step fan control
- -
- Setpoint knob
- X
- Hidden setpoint
- -
- Output
- 3-point
- Display
- -
-
RC-TO
- Occupancy button / Forced ventilation
- X
- 3-step fan control
- -
- Setpoint knob
- X
- Hidden setpoint
- -
- Output
- 3-point
- Display
- -
-
RC-DTO
- Occupancy button / Forced ventilation
- X
- 3-step fan control
- -
- Setpoint knob
- -
- Hidden setpoint
- -
- Output
- 3-point
- Display
- X
Specifications
Supply voltage | 18...30 V AC, 50...60 Hz |
---|---|
Power consumption | 2.5 VA |
Ambient temperature | 0...50°C |
Storage temperature | -20...+70°C |
Built-in temperature sensor | 0...50°C NTC linearised 15 kΩ |
Accuracy | ±0.5°C at 15...30°C |
Mounting | Room |
Protection class | IP20 |
Analogue inputs (AI) | PT1000, 0...50°C |
Condensation input (CI) | Input for Regin's condensation detector KG-A/1 |
Digital inputs (DI) | Closing potential-free contact |
Universal inputs (UI) | Analogue input (AI), PT1000 sensor, 0...100°C or digital input (DI) |
Digital outputs (DO) | 24 V AC, max. 0.5 A. |
Universal outputs (UO) | Digital output (DO) 24 V AC, max. 2.0 A or analogue output (AO), 0...10 V DC, max. 5 mA |
+C power output for DI only | 24 V DC, max. 10 mA, short circuit-protected |
Accessories

RB3
Relay unit for RC-...F... controllers

X1178
Power interface for RC-...F... controllers

KG-A/1
Condensation detector for Regio controllers, 1 m cable length

RC-CONN:10
A set of 10 connector plates for RC units

RCC-CONN:10
A set of 10 connector plates for RCC units

RC-TEST
Service adapter for all Regio room units