Regin
Pressure transmitter for liquids and gases
Pressure transmitter for measurement of liquids and gases.
Articles
(14 st)-
TTKN1- Sensor Interface
- 0-10 V
- Display
- No
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...100 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
-
TTKN1-420- Sensor Interface
- 4-20 mA
- Display
- No
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...100 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
-
TTKN2.5- Sensor Interface
- 0-10 V
- Display
- No
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...250 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
-
TTKN2.5-420- Sensor Interface
- 4-20 mA
- Display
- No
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...250 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
-
TTKN6- Sensor Interface
- 0-10 V
- Display
- No
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...600 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
-
TTKN6-420- Sensor Interface
- 4-20 mA
- Display
- No
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...600 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
-
TTKN10- Sensor Interface
- 0-10 V
- Display
- No
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...1000 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
-
TTKN10-420- Sensor Interface
- 4-20 mA
- Display
- No
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...1000 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
-
TTKN16- Sensor Interface
- 0-10 V
- Display
- No
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...1600 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
-
TTKN16-420- Sensor Interface
- 4-20 mA
- Display
- No
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...1600 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
-
TTKN25- Sensor Interface
- 0-10 V
- Display
- No
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...2500 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
-
TTKN25-420- Sensor Interface
- 4-20 mA
- Display
- No
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...2500 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
-
TTKN40- Sensor Interface
- 0-10 V
- Display
- No
- Analogue output load impedance 0...10v
- > 10000 Ω
- Measuring range
- 0...4000 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
-
TTKN40-420- Sensor Interface
- 4-20 mA
- Display
- No
- Analogue output load impedance 4...20mA
- ((Supply voltage - 7 V) / 0.02 A) Ω
- Measuring range
- 0...4000 kPa
- Accuracy, resolution sensor
- 0.1 % full scale
- Accuracy, long-term stability according to IEC EN 60770-1
- Max. ±0.25 % full scale
- Tolerable overload
- ≤ 4 bar 3.0 x full scale, > 4 bar 2.5 x full scale
Specifications
| Power Supply | 24VAC/DC (20...28 V AC 50Hz / 12...33 V DC), VA, 24VDC (7...33 V DC) |
|---|---|
| Protection class | IP67 |
| Ambient temperature | -30…85 °C |
| Storage temperature | -50…100 °C |
| Dimensions, external (WxHxD) | 24x55x mm |
| Weight, incl. packaging | 0.9 kg |
| Media | Liquids and gases |
| (Well/Pressure) connection | G 1/4 " |
| Cabel | 1.5 m three-wire, 1.5 m two-wire |
| Pressure connection | Outside thread |
| Dynamic response time | < 2 ms, 1 ms typically |
| Media temperature | -15…+125°C |
| Material sealing | FPM |
Software & documentation
Product sheet