Differential pressure transmitter for liquids and gases
Differential pressure transmitter for measurement of liquids (also glycol-mixed) and gases (not ammonia). The measuring element is made of ceramic material.
Navigate on this page
Articles
(18 st)-
DTK10Differential pressure transmitter
- Working range
- 0...10 kPa
- Output signal
- 0...10 V DC
- Max. overload pressure (one side)
- 60 kPa
- Accuracy
- ±1.3 % fs
-
DTK10-420Differential pressure transmitter
- Working range
- 0...10 kPa
- Output signal
- 4...20 mA
- Max. overload pressure (one side)
- 60 kPa
- Accuracy
- ±1.3 % fs
-
DTK20Differential pressure transmitter
- Working range
- 0...20 kPa
- Output signal
- 0...10 V DC
- Max. overload pressure (one side)
- 120 kPa
- Accuracy
- ±1.3 % fs
-
DTK20-420Differential pressure transmitter
- Working range
- 0...20 kPa
- Output signal
- 4...20 mA
- Max. overload pressure (one side)
- 120 kPa
- Accuracy
- ±1.3 % fs
-
DTK40Differential pressure transmitter
- Working range
- 0...40 kPa
- Output signal
- 0...10 V DC
- Max. overload pressure (one side)
- 200 kPa
- Accuracy
- ±1.3 % fs
-
DTK40-420Differential pressure transmitter
- Working range
- 0...40 kPa
- Output signal
- 4...20 mA
- Max. overload pressure (one side)
- 200 kPa
- Accuracy
- ±1.3 % fs
-
DTK100Differential pressure transmitter
- Working range
- 0...100 kPa
- Output signal
- 0...10 V DC
- Max. overload pressure (one side)
- 500 kPa
- Accuracy
- ±1.3 % fs
-
DTK100-420Differential pressure transmitter
- Working range
- 0...100 kPa
- Output signal
- 4...20 mA
- Max. overload pressure (one side)
- 500 kPa
- Accuracy
- ±1.3 % fs
-
DTK250Differential pressure transmitter
- Working range
- 0...250 kPa
- Output signal
- 0...10 V DC
- Max. overload pressure (one side)
- 1200 kPa
- Accuracy
- ±1.3 % fs
-
DTK250-420Differential pressure transmitter
- Working range
- 0...250 kPa
- Output signal
- 4...20 mA
- Max. overload pressure (one side)
- 1200 kPa
- Accuracy
- ±1.3 % fs
-
DTK400Differential pressure transmitter
- Working range
- 0...400 kPa
- Output signal
- 0...10 V DC
- Max. overload pressure (one side)
- 1200 kPa
- Accuracy
- ±0.8 % fs
-
DTK400-420Differential pressure transmitter
- Working range
- 0...400 kPa
- Output signal
- 4...20 mA
- Max. overload pressure (one side)
- 1200 kPa
- Accuracy
- ±0.8 % fs
-
DTK600Differential pressure transmitter
- Working range
- 0...600 kPa
- Output signal
- 0...10 V DC
- Max. overload pressure (one side)
- 1200 kPa
- Accuracy
- ±0.5 % fs
-
DTK600-420Differential pressure transmitter
- Working range
- 0...600 kPa
- Output signal
- 4...20 mA
- Max. overload pressure (one side)
- 1200 kPa
- Accuracy
- ±0.5 % fs
-
DTK1000Differential pressure transmitter
- Working range
- 0...1000 kPa
- Output signal
- 0...10 V DC
- Max. overload pressure (one side)
- 2000 kPa
- Accuracy
- ±0.5 % fs
-
DTK1000-420Differential pressure transmitter
- Working range
- 0...1000 kPa
- Output signal
- 4...20 mA
- Max. overload pressure (one side)
- 2000 kPa
- Accuracy
- ±0.5 % fs
-
DTK1600Differential pressure transmitter
- Working range
- 0...1600 kPa
- Output signal
- 0...10 V DC
- Max. overload pressure (one side)
- 3200 kPa
- Accuracy
- ±0.5 % fs
-
DTK1600-420Differential pressure transmitter
- Working range
- 0...1600 kPa
- Output signal
- 4...20 mA
- Max. overload pressure (one side)
- 3200 kPa
- Accuracy
- ±0.5 % fs
Specifications
Supply voltage | 24 V AC / 18...33 V DC (output signal 0...10 V DC), 0.1 VA 11...33 V DC, two-wire (output signal 4...20 mA), 0.5 VA |
---|---|
Ambient temperature | -15...+80°C |
Connection | Screw fitting for Ø 6 mm pipe included |
Protection class | IP65 |
Accessories

DTK-NIPPEL
Nipple (R=1/8'' 27NPT) for connection of Ø 6 mm copper pipe

DTK-R
Copper pipe, Ø 6 mm, length 30 cm. Accessory to DTK.