Industrietechnik

Capillary thermostat, IP65

High quality thermostats for use in cooling, heating and ventilation systems.

Articles

(9 st)
  • MTIC30S - Regin
    MTIC30S
    Probe diameter
    Ø 9.5 mm
    Setpoint value, temperature range
    -30...30 °C
    Step function
    1
    Hysteresis, temperature
    2...20 K
    Reset function
    Automatic
    Max. probe temperature
    60 °C
    Probe length
    1.5 m
    Setpoint adjustment
    External
    Suitable immersion well
    DBZ-01, DBZ-02
  • MTIC30SH - Regin
    MTIC30SH
    Probe diameter
    Ø 9.5 mm
    Setpoint value, temperature range
    -30...30 °C
    Step function
    1
    Hysteresis, temperature
    2...20 K
    Reset function
    Automatic
    Max. probe temperature
    60 °C
    Probe length
    1.5 m
    Setpoint adjustment
    Internal
    Suitable immersion well
    DR-01/02
  • MTIC30-2 - Regin
    MTIC30-2
    Probe diameter
    Ø 9.5 mm
    Setpoint value, temperature range
    -30...30 °C
    Step function
    2
    Hysteresis, temperature
    1 K
    Step differential
    2...5 K
    Reset function
    Automatic
    Max. probe temperature
    60 °C
    Probe length
    1.5 m
    Setpoint adjustment
    External
  • MTIC30 - Regin
    MTIC30
    Probe diameter
    Ø 9.5 mm
    Setpoint value, temperature range
    -30...30 °C
    Step function
    1
    Hysteresis, temperature
    1 K
    Reset function
    Automatic
    Max. probe temperature
    60 °C
    Probe length
    1.5 m
    Setpoint adjustment
    External
    Suitable immersion well
    DR-01/02
  • MTIC90S - Regin
    MTIC90S
    Probe diameter
    Ø 9.5 mm
    Setpoint value, temperature range
    20...90 °C
    Step function
    1
    Hysteresis, temperature
    2...20 K
    Reset function
    Automatic
    Max. probe temperature
    100 °C
    Probe length
    1.5 m
    Setpoint adjustment
    External
    Suitable immersion well
    DR-01/02
  • MTIC90SH - Regin
    MTIC90SH
    Probe diameter
    Ø 9.5 mm
    Setpoint value, temperature range
    20...90 °C
    Step function
    1
    Hysteresis, temperature
    2...20 K
    Reset function
    Automatic
    Max. probe temperature
    100 °C
    Probe length
    1.5 m
    Setpoint adjustment
    Internal
    Suitable immersion well
    DR-01/02
  • MTIC90 - Regin
    MTIC90
    Probe diameter
    Ø 9.5 mm
    Setpoint value, temperature range
    20...90 °C
    Step function
    1
    Hysteresis, temperature
    1 K
    Reset function
    Automatic
    Max. probe temperature
    100 °C
    Probe length
    1.5 m
    Setpoint adjustment
    External
    Suitable immersion well
    DR-01/02
  • MTIC90R - Regin
    MTIC90R
    Probe diameter
    Ø 9.5 mm
    Setpoint value, temperature range
    20...90 °C
    Step function
    1
    Hysteresis, temperature
    Maximum manual reset
    Reset function
    Manual
    Max. probe temperature
    100 °C
    Probe length
    1.5 m
    Setpoint adjustment
    External
    Suitable immersion well
    DR-01/02
  • MTIC120S - Regin
    MTIC120S
    Probe diameter
    Ø 8 mm
    Setpoint value, temperature range
    50...120 °C
    Step function
    1
    Hysteresis, temperature
    1 K
    Reset function
    Automatic
    Max. probe temperature
    150 °C
    Probe length
    1.5 m
    Setpoint adjustment
    External
    Suitable immersion well
    DR-16/17

Specifications

Specifications for Capillary thermostat, IP65
Sensor element Liquid-filled copper capillary
Electrical contact SPDT microswitch
Switching capacity 15 (8) A, 24…250 V AC
Appliance class Class I
Protection class IP65
Ambient humidity (non-condensing) 10…90 % RH
Ambient temperature -35…65 °C
Storage temperature -40…70 °C
Storage humidity 10...95 % RH
Dimensions, external (WxHxD) 70x86x108 mm, 70x72x108 mm
Weight, incl. packaging 0.4 kg
Material, cover ABS
Material, base PC+ABS blend (Bayblend®)

Accessories

DR-01
Regin DR-01

Brass pocket 120mm, Ø external 11 mm, Ø internal 10 mm, connection R 1/2”

Tube length
120 mm
Total well length
140 mm
External tube diameter
11 mm
DR-02
Industrietechnik DR-02

Stainless steel pocket AISI 304, 120 mm, Ø external 12 mm, Ø internal 10 mm, connection R 1/2”

Tube length
120 mm
Total well length
148 mm
External tube diameter
12 mm
DR-05
Industrietechnik DR-05

Set of mounting brackets for capillary fixing

Fixing stopper for capillary
Set of 6 mounting plastic brackets
DR-16
Regin DR-16

Brass pocket 120mm, Ø external 10 mm, Ø internal 8,5 mm, connection R 1/2”

Tube length
120 mm
Total well length
140 mm
External tube diameter
10 mm
DR-17
Industrietechnik DR-17

Stainless steel pocket AISI 304, 120 mm, Ø external 10mm, Ø internal 8,5 mm, connection R 1/2”

Tube length
120 mm
Total well length
148 mm
External tube diameter
10 mm
You´re on International site Change sales company?
Benelux Denmark France Germany (Redirect to: deos-ag.com) Italy (Redirect to: industrietechnik.it) Sweden