Regin

Flanged ultrasonic energy meters

Flanged ultrasonic energy meters, intended for heating or cooling.We offer many different options, see the product sheet for more information.

Articles

(14 st)
  • SSCU25-3.5-CR-M - Regin
    SSCU25-3.5-CR-M
    Power Supply
    Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
    Nominal diameter
    DN25
    Flow, Qp
    3.5 m³/h
    Type of measurement
    Cooling
    Communication interface
    M-Bus
    Length of flow meter
    260 mm
    Media
    Water only
  • SSCU25-3.5-HR-M - Regin
    SSCU25-3.5-HR-M
    Power Supply
    Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
    Nominal diameter
    DN25
    Flow, Qp
    3.5 m³/h
    Type of measurement
    Heating
    Communication interface
    M-Bus
    Length of flow meter
    260 mm
    Media
    Water only
  • SSCU25-6.0-CR-M - Regin
    SSCU25-6.0-CR-M
    Power Supply
    Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
    Nominal diameter
    DN25
    Flow, Qp
    6 m³/h
    Type of measurement
    Cooling
    Communication interface
    M-Bus
    Length of flow meter
    260 mm
    Media
    Water only
  • SSCU25-6.0-HR-M - Regin
    SSCU25-6.0-HR-M
    Power Supply
    Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
    Nominal diameter
    DN25
    Flow, Qp
    6 m³/h
    Type of measurement
    Heating
    Communication interface
    M-Bus
    Length of flow meter
    260 mm
    Media
    Water only
  • SSCU40-10-CR-M - Regin
    SSCU40-10-CR-M
    Power Supply
    Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
    Nominal diameter
    DN40
    Flow, Qp
    10 m³/h
    Type of measurement
    Cooling
    Communication interface
    M-Bus
    Length of flow meter
    300 mm
    Media
    Water only
  • SSCU40-10-HR-M - Regin
    SSCU40-10-HR-M
    Power Supply
    Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
    Nominal diameter
    DN40
    Flow, Qp
    10 m³/h
    Type of measurement
    Heating
    Communication interface
    M-Bus
    Length of flow meter
    300 mm
    Media
    Water only
  • SSCU50-15-CR-M - Regin
    SSCU50-15-CR-M
    Power Supply
    Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
    Nominal diameter
    DN50
    Flow, Qp
    15 m³/h
    Type of measurement
    Cooling
    Communication interface
    M-Bus
    Length of flow meter
    270 mm
    Media
    Water only
  • SSCU50-15-HR-M - Regin
    SSCU50-15-HR-M
    Power Supply
    Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
    Nominal diameter
    DN50
    Flow, Qp
    15 m³/h
    Type of measurement
    Heating
    Communication interface
    M-Bus
    Length of flow meter
    270 mm
    Media
    Water only
  • SSCU65-25-CR-M - Regin
    SSCU65-25-CR-M
    Power Supply
    Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
    Nominal diameter
    DN65
    Flow, Qp
    25 m³/h
    Type of measurement
    Cooling
    Communication interface
    M-Bus
    Length of flow meter
    300 mm
    Media
    Water only
  • SSCU65-25-HR-M - Regin
    SSCU65-25-HR-M
    Power Supply
    Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
    Nominal diameter
    DN65
    Flow, Qp
    25 m³/h
    Type of measurement
    Heating
    Communication interface
    M-Bus
    Length of flow meter
    300 mm
    Media
    Water only
  • SSCU80-40-CR-M - Regin
    SSCU80-40-CR-M
    Power Supply
    Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
    Nominal diameter
    DN80
    Flow, Qp
    40 m³/h
    Type of measurement
    Cooling
    Communication interface
    M-Bus
    Length of flow meter
    300 mm
    Media
    Water only
  • SSCU80-40-HR-M - Regin
    SSCU80-40-HR-M
    Power Supply
    Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
    Nominal diameter
    DN80
    Flow, Qp
    40 m³/h
    Type of measurement
    Heating
    Communication interface
    M-Bus
    Length of flow meter
    300 mm
    Media
    Water only
  • SSCU100-60-CR-M - Regin
    SSCU100-60-CR-M
    Power Supply
    Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
    Nominal diameter
    DN100
    Flow, Qp
    60 m³/h
    Type of measurement
    Cooling
    Communication interface
    M-Bus
    Length of flow meter
    360 mm
    Media
    Water only
  • SSCU100-60-HR-M - Regin
    SSCU100-60-HR-M
    Power Supply
    Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V or 230 V power pack available as accessory.
    Nominal diameter
    DN100
    Flow, Qp
    60 m³/h
    Type of measurement
    Heating
    Communication interface
    M-Bus
    Length of flow meter
    360 mm
    Media
    Water only

Specifications

Specifications for Flanged ultrasonic energy meters
Protection class IP54
Ambient humidity (non-condensing) 5…95 % RH
Ambient temperature 5…55 °C
Storage temperature 1…60 °C
Temperature range cooling 0...50 °C
Temperature range heating 0...150 °C
Temperature resolution 0.01 °C
Measurement cycle, temperature 2...60 s
Measurement cycle, flow 2 s
Display LCD, 8 digits + special characters
Display units MWh, kW, GJ, m 3 , m 3 /h (kWh, GJ, l , l/h, MW, MMBTU, Gcal), 3 decimal places. The unit for energy consumption can only be set while the energy consumption is ≤ 10 kWh.
Mechanical class Class M2 (MID: 31.03.2004 annex I)
EMC Class E2 (MID: 31.03.2004 annex I)
Cable length temperature sensor 3 m
Diameter temperature sensor 6 mm
Temperature sensor installation Indirect in a temperature sensor pocket per EN1434
Temperature sensor requirements, heat meter EU (MID) identification on the temperature sensors
Temperature sensor requirements, cooling meter National German approval as a temperature sensor for cooling meters. Requirements in other countries may be different
Flow meter mounting position Horizontal or vertical, the transducers (black housing) to the side of or under the measuring tube for cooling applications
Flow meter, point of installation Return flow (if forward flow installation is needed, the installation position can be changed with the main button)
Flow meter temperature range Heating 10…130 °C
Measuring principle Ultrasonic; time-of-flight
Accuracy according to MID Class 2

Accessories

TH-120-1/2
Regin TH-120-1/2

Temperature sensor pocket for installation of universal temperature sensor with 6 mm sheath diameter

Compatible with
15...100 m³/h
Connection A
G1/2"
Installation length
120 mm
POWERPACK-EM-24
Regin POWERPACK-EM-24

24 V AC power pack

BATTERY-EM
Regin BATTERY-EM

Battery for SSU and SSCU

POWERPACK-EM
Regin POWERPACK-EM

230 V power pack

OPTO-TOOL
Regin OPTO-TOOL

Software device monitor

OPTO-CABLE-USB
Regin OPTO-CABLE-USB

Optocoupler with USB interface

TH-85-1/2
Regin TH-85-1/2

Temperature sensor pocket for installation of universal temperature sensor with 6 mm sheath diameter

Compatible with
q p 3.5…10 m 3 /h
Connection A
G½
Installation length
85 mm
You´re on France site
Change language? English français (France)
Change sales company?
Benelux Denmark Germany (Redirect to: deos-ag.com) International Italy (Redirect to: industrietechnik.it) Sweden