Flanged ultrasonic energy meters

Flanged ultrasonic energy meters, intended for heating or cooling.We offer many different options, see the product sheet for more information.

Articles

(42 st)
  • SSCU25-3.5-CR-PO - Regin
    SSCU25-3.5-CR-PO
    Nominal diameter
    DN25
    Flow
    3.5 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    Pulse output for energy
    Length of flow meter
    260 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU25-3.5-CR-M - Regin
    SSCU25-3.5-CR-M
    Nominal diameter
    DN25
    Flow
    3.5 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus
    Length of flow meter
    260 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU25-3.5-CR-MPI - Regin
    SSCU25-3.5-CR-MPI
    Nominal diameter
    DN25
    Flow
    3.5 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    260 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU25-3.5-HR-M - Regin
    SSCU25-3.5-HR-M
    Nominal diameter
    DN25
    Flow
    3.5 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus
    Length of flow meter
    260 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU25-3.5-HR-MPI - Regin
    SSCU25-3.5-HR-MPI
    Nominal diameter
    DN25
    Flow
    3.5 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    260 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU25-3.5-HR-PO - Regin
    SSCU25-3.5-HR-PO
    Nominal diameter
    DN25
    Flow
    3.5 m 3 /h
    Type of measurement
    Heating
    Communication interface
    Pulse output for energy
    Length of flow meter
    260 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU25-6.0-CR-M - Regin
    SSCU25-6.0-CR-M
    Nominal diameter
    DN25
    Flow
    6.0 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus
    Length of flow meter
    260 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU25-6.0-CR-MPI - Regin
    SSCU25-6.0-CR-MPI
    Nominal diameter
    DN25
    Flow
    6.0 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    260 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU25-6.0-CR-PO - Regin
    SSCU25-6.0-CR-PO
    Nominal diameter
    DN25
    Flow
    6.0 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    Pulse output for energy
    Length of flow meter
    260 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU25-6.0-HR-M - Regin
    SSCU25-6.0-HR-M
    Nominal diameter
    DN25
    Flow
    6.0 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus
    Length of flow meter
    260 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU25-6.0-HR-MPI - Regin
    SSCU25-6.0-HR-MPI
    Nominal diameter
    DN25
    Flow
    6.0 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    260 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU25-6.0-HR-PO - Regin
    SSCU25-6.0-HR-PO
    Nominal diameter
    DN25
    Flow
    6.0 m 3 /h
    Type of measurement
    Heating
    Communication interface
    Pulse output for energy
    Length of flow meter
    260 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU40-10-CR-M - Regin
    SSCU40-10-CR-M
    Nominal diameter
    DN40
    Flow
    10 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus
    Length of flow meter
    300 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU40-10-CR-MPI - Regin
    SSCU40-10-CR-MPI
    Nominal diameter
    DN40
    Flow
    10 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    300 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU40-10-CR-PO - Regin
    SSCU40-10-CR-PO
    Nominal diameter
    DN40
    Flow
    10 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    Pulse output for energy
    Length of flow meter
    300 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU40-10-HR-M - Regin
    SSCU40-10-HR-M
    Nominal diameter
    DN40
    Flow
    10 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus
    Length of flow meter
    300 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU40-10-HR-MPI - Regin
    SSCU40-10-HR-MPI
    Nominal diameter
    DN40
    Flow
    10 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    300 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU40-10-HR-PO - Regin
    SSCU40-10-HR-PO
    Nominal diameter
    DN40
    Flow
    10 m 3 /h
    Type of measurement
    Heating
    Communication interface
    Pulse output for energy
    Length of flow meter
    300 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU50-15-CR-M - Regin
    SSCU50-15-CR-M
    Nominal diameter
    DN50
    Flow
    15 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus
    Length of flow meter
    270 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU50-15-CR-MPI - Regin
    SSCU50-15-CR-MPI
    Nominal diameter
    DN50
    Flow
    15 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    270 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU50-15-CR-PO - Regin
    SSCU50-15-CR-PO
    Nominal diameter
    DN50
    Flow
    15 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    Pulse output for energy
    Length of flow meter
    270 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU50-15-HR-M - Regin
    SSCU50-15-HR-M
    Nominal diameter
    DN50
    Flow
    15 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus
    Length of flow meter
    270 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU50-15-HR-MPI - Regin
    SSCU50-15-HR-MPI
    Nominal diameter
    DN50
    Flow
    15 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    270 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU50-15-HR-PO - Regin
    SSCU50-15-HR-PO
    Nominal diameter
    DN50
    Flow
    15 m 3 /h
    Type of measurement
    Heating
    Communication interface
    Pulse output for energy
    Length of flow meter
    270 mm
    Flanges
    PN25 with 4 bolt holes
  • SSCU65-25-CR-M - Regin
    SSCU65-25-CR-M
    Nominal diameter
    DN65
    Flow
    25 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus
    Length of flow meter
    300 mm
    Flanges
    PN25 with 8 bolt holes
  • SSCU65-25-CR-MPI - Regin
    SSCU65-25-CR-MPI
    Nominal diameter
    DN65
    Flow
    25 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    300 mm
    Flanges
    PN25 with 8 bolt holes
  • SSCU65-25-CR-PO - Regin
    SSCU65-25-CR-PO
    Nominal diameter
    DN65
    Flow
    25 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    Pulse output for energy
    Length of flow meter
    300 mm
    Flanges
    PN25 with 8 bolt holes
  • SSCU65-25-HR-M - Regin
    SSCU65-25-HR-M
    Nominal diameter
    DN65
    Flow
    25 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus
    Length of flow meter
    300 mm
    Flanges
    PN25 with 8 bolt holes
  • SSCU65-25-HR-MPI - Regin
    SSCU65-25-HR-MPI
    Nominal diameter
    DN65
    Flow
    25 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    300 mm
    Flanges
    PN25 with 8 bolt holes
  • SSCU65-25-HR-PO - Regin
    SSCU65-25-HR-PO
    Nominal diameter
    DN65
    Flow
    25 m 3 /h
    Type of measurement
    Heating
    Communication interface
    Pulse output for energy
    Length of flow meter
    300 mm
    Flanges
    PN25 with 8 bolt holes
  • SSCU80-40-CR-M - Regin
    SSCU80-40-CR-M
    Nominal diameter
    DN80
    Flow
    40 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus
    Length of flow meter
    300 mm
    Flanges
    PN25 with 8 bolt holes
  • SSCU80-40-CR-MPI - Regin
    SSCU80-40-CR-MPI
    Nominal diameter
    DN80
    Flow
    40 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    300 mm
    Flanges
    PN25 with 8 bolt holes
  • SSCU80-40-CR-PO - Regin
    SSCU80-40-CR-PO
    Nominal diameter
    DN80
    Flow
    40 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    Pulse output for energy
    Length of flow meter
    300 mm
    Flanges
    PN25 with 8 bolt holes
  • SSCU80-40-HR-M - Regin
    SSCU80-40-HR-M
    Nominal diameter
    DN80
    Flow
    40 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus
    Length of flow meter
    300 mm
    Flanges
    PN25 with 8 bolt holes
  • SSCU80-40-HR-MPI - Regin
    SSCU80-40-HR-MPI
    Nominal diameter
    DN80
    Flow
    40 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    300 mm
    Flanges
    PN25 with 8 bolt holes
  • SSCU80-40-HR-PO - Regin
    SSCU80-40-HR-PO
    Nominal diameter
    DN80
    Flow
    40 m 3 /h
    Type of measurement
    Heating
    Communication interface
    Pulse output for energy
    Length of flow meter
    300 mm
    Flanges
    PN25 with 8 bolt holes
  • SSCU100-60-CR-M - Regin
    SSCU100-60-CR-M
    Nominal diameter
    DN100
    Flow
    60 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus
    Length of flow meter
    360 mm
    Flanges
    PN25 with 8 bolt holes
  • SSCU100-60-CR-MPI - Regin
    SSCU100-60-CR-MPI
    Nominal diameter
    DN100
    Flow
    60 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    360 mm
    Flanges
    PN25 with 8 bolt holes
  • SSCU100-60-CR-PO - Regin
    SSCU100-60-CR-PO
    Nominal diameter
    DN100
    Flow
    60 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    Pulse output for energy
    Length of flow meter
    360 mm
    Flanges
    PN25 with 8 bolt holes
  • SSCU100-60-HR-M - Regin
    SSCU100-60-HR-M
    Nominal diameter
    DN100
    Flow
    60 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus
    Length of flow meter
    360 mm
    Flanges
    PN25 with 8 bolt holes
  • SSCU100-60-HR-MPI - Regin
    SSCU100-60-HR-MPI
    Nominal diameter
    DN100
    Flow
    60 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    360 mm
    Flanges
    PN25 with 8 bolt holes
  • SSCU100-60-HR-PO - Regin
    SSCU100-60-HR-PO
    Nominal diameter
    DN100
    Flow
    60 m 3 /h
    Type of measurement
    Heating
    Communication interface
    Pulse output for energy
    Length of flow meter
    360 mm
    Flanges
    PN25 with 8 bolt holes
Specifications for Flanged ultrasonic energy meters
Power supply 3 V lithium battery, min. 10 years. 24 V and 230 V power packs are available as accessories.
Temperature range 0…150 °C heating, 0…50°C cooling, 5…130°C
Temperature difference limits 3…100K
Temperature resolution 0.01°C
Temperature range, cooling (energy meeter) 5…50 °C
Storage temperature -20…+60°C
Ambient humidity < 93 % RH
Protection class IP54
Calculation of heat from K ΔΘ > 0.05K
Calculation of cooling from K ΔΘ < -0.05K
Dual purpose heat/cooling meter ΔΘHC < -0.5K
Measurement frequency at q p Cycle 30 s
Data storage EEPROM, daily storage of values
Interfaces M-Bus, pulse output or M-Bus with 2 pulse inputs
Reading dates Annual billing date selectable, 24 monthly values
Display LCD, 8 digits + additional symbols
Display units MWh, kWh, GJ, m 3 , m 3 /h, l/h, kW, MW, °C
Mechanical class Class M1 (MID: 31.03.2004 annex I)
EMC Class E1 (MID: 31.03.2004 annex I)
Environmental class A (EN 1434)
Cable length 3m
Sensor element PT500; separately approved type as per EN60751, unshielded
Diameter, sensor 6mm
Installation Direct or indirect in a temperature sensor pocket per EN1434
Temperature sensor requirements, heat meter EU (MID) identification on the temperature sensors
Temperature sensor requirements, cooling meter National German approval as a temperature sensor for cooling meters. Requirements in other countries may be different.
Connection Flanged according to EN 1092-3
Pressure rating PN25
Media Water
Mounting position Horizontal or vertical
Mounting position, cooling Transducers (black housing) to the side of or under the measuring tube
Point of installation Return flow
Temperature range, heating 10…130°C
Temperature range, cooling 5…50°C
Recommended minimum system pressure 1 bar
TH-85-1/2

Temperature sensor pocket for installation of universal temperature sensor with 6 mm sheath diameter

TH-120-1/2

Temperature sensor pocket for installation of universal temperature sensor with 6 mm sheath diameter

OPTO-CABLE-USB

Optocoupler with USB interface

OPTO-TOOL

Software device monitor

POWERPACK-EM

230 V power pack

POWERPACK-EM-24

24 V AC power pack

BATTERY-EM

Battery for SSU and SSCU