Flanged ultrasonic energy meters
Flanged ultrasonic energy meters, intended for heating or cooling.We offer many different options, see the product sheet for more information.
Navigate on this page
Articles
(42 st)-
SSCU25-3.5-CR-PO
- Nominal diameter
- DN25
- Flow
- 3.5 m 3 /h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
- Length of flow meter
- 260 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU25-3.5-CR-M
- Nominal diameter
- DN25
- Flow
- 3.5 m 3 /h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
- Length of flow meter
- 260 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU25-3.5-CR-MPI
- Nominal diameter
- DN25
- Flow
- 3.5 m 3 /h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 260 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU25-3.5-HR-M
- Nominal diameter
- DN25
- Flow
- 3.5 m 3 /h
- Type of measurement
- Heating
- Communication interface
- M-Bus
- Length of flow meter
- 260 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU25-3.5-HR-MPI
- Nominal diameter
- DN25
- Flow
- 3.5 m 3 /h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 260 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU25-3.5-HR-PO
- Nominal diameter
- DN25
- Flow
- 3.5 m 3 /h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
- Length of flow meter
- 260 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU25-6.0-CR-M
- Nominal diameter
- DN25
- Flow
- 6.0 m 3 /h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
- Length of flow meter
- 260 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU25-6.0-CR-MPI
- Nominal diameter
- DN25
- Flow
- 6.0 m 3 /h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 260 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU25-6.0-CR-PO
- Nominal diameter
- DN25
- Flow
- 6.0 m 3 /h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
- Length of flow meter
- 260 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU25-6.0-HR-M
- Nominal diameter
- DN25
- Flow
- 6.0 m 3 /h
- Type of measurement
- Heating
- Communication interface
- M-Bus
- Length of flow meter
- 260 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU25-6.0-HR-MPI
- Nominal diameter
- DN25
- Flow
- 6.0 m 3 /h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 260 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU25-6.0-HR-PO
- Nominal diameter
- DN25
- Flow
- 6.0 m 3 /h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
- Length of flow meter
- 260 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU40-10-CR-M
- Nominal diameter
- DN40
- Flow
- 10 m 3 /h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
- Length of flow meter
- 300 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU40-10-CR-MPI
- Nominal diameter
- DN40
- Flow
- 10 m 3 /h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 300 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU40-10-CR-PO
- Nominal diameter
- DN40
- Flow
- 10 m 3 /h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
- Length of flow meter
- 300 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU40-10-HR-M
- Nominal diameter
- DN40
- Flow
- 10 m 3 /h
- Type of measurement
- Heating
- Communication interface
- M-Bus
- Length of flow meter
- 300 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU40-10-HR-MPI
- Nominal diameter
- DN40
- Flow
- 10 m 3 /h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 300 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU40-10-HR-PO
- Nominal diameter
- DN40
- Flow
- 10 m 3 /h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
- Length of flow meter
- 300 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU50-15-CR-M
- Nominal diameter
- DN50
- Flow
- 15 m 3 /h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
- Length of flow meter
- 270 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU50-15-CR-MPI
- Nominal diameter
- DN50
- Flow
- 15 m 3 /h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 270 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU50-15-CR-PO
- Nominal diameter
- DN50
- Flow
- 15 m 3 /h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
- Length of flow meter
- 270 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU50-15-HR-M
- Nominal diameter
- DN50
- Flow
- 15 m 3 /h
- Type of measurement
- Heating
- Communication interface
- M-Bus
- Length of flow meter
- 270 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU50-15-HR-MPI
- Nominal diameter
- DN50
- Flow
- 15 m 3 /h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 270 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU50-15-HR-PO
- Nominal diameter
- DN50
- Flow
- 15 m 3 /h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
- Length of flow meter
- 270 mm
- Flanges
- PN25 with 4 bolt holes
-
SSCU65-25-CR-M
- Nominal diameter
- DN65
- Flow
- 25 m 3 /h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
- Length of flow meter
- 300 mm
- Flanges
- PN25 with 8 bolt holes
-
SSCU65-25-CR-MPI
- Nominal diameter
- DN65
- Flow
- 25 m 3 /h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 300 mm
- Flanges
- PN25 with 8 bolt holes
-
SSCU65-25-CR-PO
- Nominal diameter
- DN65
- Flow
- 25 m 3 /h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
- Length of flow meter
- 300 mm
- Flanges
- PN25 with 8 bolt holes
-
SSCU65-25-HR-M
- Nominal diameter
- DN65
- Flow
- 25 m 3 /h
- Type of measurement
- Heating
- Communication interface
- M-Bus
- Length of flow meter
- 300 mm
- Flanges
- PN25 with 8 bolt holes
-
SSCU65-25-HR-MPI
- Nominal diameter
- DN65
- Flow
- 25 m 3 /h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 300 mm
- Flanges
- PN25 with 8 bolt holes
-
SSCU65-25-HR-PO
- Nominal diameter
- DN65
- Flow
- 25 m 3 /h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
- Length of flow meter
- 300 mm
- Flanges
- PN25 with 8 bolt holes
-
SSCU80-40-CR-M
- Nominal diameter
- DN80
- Flow
- 40 m 3 /h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
- Length of flow meter
- 300 mm
- Flanges
- PN25 with 8 bolt holes
-
SSCU80-40-CR-MPI
- Nominal diameter
- DN80
- Flow
- 40 m 3 /h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 300 mm
- Flanges
- PN25 with 8 bolt holes
-
SSCU80-40-CR-PO
- Nominal diameter
- DN80
- Flow
- 40 m 3 /h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
- Length of flow meter
- 300 mm
- Flanges
- PN25 with 8 bolt holes
-
SSCU80-40-HR-M
- Nominal diameter
- DN80
- Flow
- 40 m 3 /h
- Type of measurement
- Heating
- Communication interface
- M-Bus
- Length of flow meter
- 300 mm
- Flanges
- PN25 with 8 bolt holes
-
SSCU80-40-HR-MPI
- Nominal diameter
- DN80
- Flow
- 40 m 3 /h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 300 mm
- Flanges
- PN25 with 8 bolt holes
-
SSCU80-40-HR-PO
- Nominal diameter
- DN80
- Flow
- 40 m 3 /h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
- Length of flow meter
- 300 mm
- Flanges
- PN25 with 8 bolt holes
-
SSCU100-60-CR-M
- Nominal diameter
- DN100
- Flow
- 60 m 3 /h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
- Length of flow meter
- 360 mm
- Flanges
- PN25 with 8 bolt holes
-
SSCU100-60-CR-MPI
- Nominal diameter
- DN100
- Flow
- 60 m 3 /h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 360 mm
- Flanges
- PN25 with 8 bolt holes
-
SSCU100-60-CR-PO
- Nominal diameter
- DN100
- Flow
- 60 m 3 /h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
- Length of flow meter
- 360 mm
- Flanges
- PN25 with 8 bolt holes
-
SSCU100-60-HR-M
- Nominal diameter
- DN100
- Flow
- 60 m 3 /h
- Type of measurement
- Heating
- Communication interface
- M-Bus
- Length of flow meter
- 360 mm
- Flanges
- PN25 with 8 bolt holes
-
SSCU100-60-HR-MPI
- Nominal diameter
- DN100
- Flow
- 60 m 3 /h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
- Length of flow meter
- 360 mm
- Flanges
- PN25 with 8 bolt holes
-
SSCU100-60-HR-PO
- Nominal diameter
- DN100
- Flow
- 60 m 3 /h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
- Length of flow meter
- 360 mm
- Flanges
- PN25 with 8 bolt holes
Specifications
Power supply | 3 V lithium battery, min. 10 years. 24 V and 230 V power packs are available as accessories. |
---|---|
Temperature range | 0…150 °C heating, 0…50°C cooling, 5…130°C |
Temperature difference limits | 3…100K |
Temperature resolution | 0.01°C |
Temperature range, cooling (energy meeter) | 5…50 °C |
Storage temperature | -20…+60°C |
Ambient humidity | < 93 % RH |
Protection class | IP54 |
Calculation of heat from K | ΔΘ > 0.05K |
Calculation of cooling from K | ΔΘ < -0.05K |
Dual purpose heat/cooling meter | ΔΘHC < -0.5K |
Measurement frequency at q p | Cycle 30 s |
Data storage | EEPROM, daily storage of values |
Interfaces | M-Bus, pulse output or M-Bus with 2 pulse inputs |
Reading dates | Annual billing date selectable, 24 monthly values |
Display | LCD, 8 digits + additional symbols |
Display units | MWh, kWh, GJ, m 3 , m 3 /h, l/h, kW, MW, °C |
Mechanical class | Class M1 (MID: 31.03.2004 annex I) |
EMC | Class E1 (MID: 31.03.2004 annex I) |
Environmental class | A (EN 1434) |
Cable length | 3m |
Sensor element | PT500; separately approved type as per EN60751, unshielded |
Diameter, sensor | 6mm |
Installation | Direct or indirect in a temperature sensor pocket per EN1434 |
Temperature sensor requirements, heat meter | EU (MID) identification on the temperature sensors |
Temperature sensor requirements, cooling meter | National German approval as a temperature sensor for cooling meters. Requirements in other countries may be different. |
Connection | Flanged according to EN 1092-3 |
Pressure rating | PN25 |
Media | Water |
Mounting position | Horizontal or vertical |
Mounting position, cooling | Transducers (black housing) to the side of or under the measuring tube |
Point of installation | Return flow |
Temperature range, heating | 10…130°C |
Temperature range, cooling | 5…50°C |
Recommended minimum system pressure | 1 bar |
Software & documentation
Accessories

TH-85-1/2
Temperature sensor pocket for installation of universal temperature sensor with 6 mm sheath diameter

TH-120-1/2
Temperature sensor pocket for installation of universal temperature sensor with 6 mm sheath diameter

OPTO-CABLE-USB
Optocoupler with USB interface

OPTO-TOOL
Software device monitor

POWERPACK-EM
230 V power pack

POWERPACK-EM-24
24 V AC power pack

BATTERY-EM
Battery for SSU and SSCU