RDAS 7 Nm

Damper actuator with spring return, 7 Nm. For 2-point (on/off) or 0…10V control signal.

Articles

(5 st)
  • RDAS7S-230 - Regin
    RDAS7S-230
    7 Nm, on/off, 230 V, spring return
    Supply voltage
    230 V AC (100…240 V AC 50/60 Hz)
    Power consumption
    7 VA (4.5 W - Running / 3.5 W Holding)
    Torque
    7 Nm
    Running time, actuator
    90 s
    Running time, spring
    15 s
    Auxiliary switch
    No
    Angle limitation
    95 °
    Damper shaft, round
    6.4…20.5mm mm
    Damper shaft, square
    6.4…13mm mm
    Damper shaft, min shaft length
    20 mm
    Max damper size (area)
    1.5 m²
  • RDAS7S-230S - Regin
    RDAS7S-230S
    7 Nm, on/off, 230 V, spring return, aux. switch
    Supply voltage
    230 V AC (100…240 V AC 50/60 Hz)
    Power consumption
    7 VA (4.5 W - Running / 3.5 W Holding)
    Torque
    7 Nm
    Running time, actuator
    90 s
    Running time, spring
    15 s
    Auxiliary switch
    Yes
    Angle limitation
    95 °
    Damper shaft, round
    6.4…20.5mm mm
    Damper shaft, square
    6.4…13mm mm
    Damper shaft, min shaft length
    20 mm
    Max damper size (area)
    1.5 m²
  • RDAS7S-24 - Regin
    RDAS7S-24
    7 Nm, on/off, 24 V, spring return
    Supply voltage
    24 V AC/DC (20…28 V AC 50/60 Hz / 24…48 V DC)
    Power consumption
    5 VA (3.5 W - Running / 2 W - Holding)
    Torque
    7 Nm
    Running time, actuator
    90 s
    Running time, spring
    15 s
    Auxiliary switch
    No
    Angle limitation
    95 °
    Damper shaft, round
    6.4…20.5mm mm
    Damper shaft, square
    6.4…13mm mm
    Damper shaft, min shaft length
    20 mm
    Max damper size (area)
    1.5 m²
  • RDAS7S-24S - Regin
    RDAS7S-24S
    7 Nm, on/off, 24 V, spring return, aux. switch
    Supply voltage
    24 V AC/DC (20…28 V AC 50/60 Hz / 24…48 V DC)
    Power consumption
    5 VA (3.5 W - Running / 2 W - Holding)
    Torque
    7 Nm
    Running time, actuator
    90 s
    Running time, spring
    15 s
    Auxiliary switch
    Yes
    Angle limitation
    95 °
    Damper shaft, round
    6.4…20.5mm mm
    Damper shaft, square
    6.4…13mm mm
    Damper shaft, min shaft length
    20 mm
    Max damper size (area)
    1.5 m²
  • RDAS7S-24A - Regin
    RDAS7S-24A
    7 Nm, 0-10 V, 24 V, spring return
    Supply voltage
    24 V AC/DC (20…28 V AC 50/60 Hz / 24…48 V DC)
    Power consumption
    5 VA (3.5 W - Running / 2 W - Holding)
    Torque
    7 Nm
    Running time, actuator
    90 s
    Running time, spring
    15 s
    Auxiliary switch
    No
    Angle limitation
    95 °
    Damper shaft, round
    6.4…20.5mm mm
    Damper shaft, square
    6.4…13mm mm
    Damper shaft, min shaft length
    20 mm
    Max damper size (area)
    1.5 m²

Specifications

Specifications for RDAS 7 Nm
Appliance class Class III
Protection class IP54
Ambient humidity (non-condensing) 0…95 % RH
Ambient temp -32…55 °C
Storage temp -32…70 °C
Cable length 0.9 m
Cable nominal cross section 0.75 mm²
Cable length extension, maximum 300 m
Working angle, rotation 90 °