Regin
Differential pressure transmitter for liquids and gases
Differential pressure transmitter for measurement of liquids (also glycol-mixed) and gases (not ammonia). The measuring element is made of ceramic material. Bracket is not included, use DTK-BRACKET if bracket is needed,
Articles
(18 st)-
DTK10Differential pressure transmitter- Sensor Interface
- 0-10 V
- Display
- No
- Analogue output load impedance 0...10v
- > 10kOhm
- Measuring range
- 0-10 kPa
- Max. overload pressure
- 60 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±1.3 % fs
-
DTK10-420Differential pressure transmitter- Sensor Interface
- 4-20 mA
- Display
- No
- Analogue output load impedance 4...20mA
- <650 Ohm (at 24 V DC)
- Measuring range
- 0-10 kPa
- Max. overload pressure
- 60 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±1.3 % fs
-
DTK20Differential pressure transmitter- Sensor Interface
- 0-10 V
- Display
- No
- Analogue output load impedance 0...10v
- > 10kOhm
- Measuring range
- 0-20 kPa
- Max. overload pressure
- 120 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±1.3 % fs
-
DTK20-420Differential pressure transmitter- Sensor Interface
- 4-20 mA
- Display
- No
- Analogue output load impedance 4...20mA
- <650 Ohm (at 24 V DC)
- Measuring range
- 0-20 kPa
- Max. overload pressure
- 120 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±1.3 % fs
-
DTK40Differential pressure transmitter- Sensor Interface
- 0-10 V
- Display
- No
- Analogue output load impedance 0...10v
- > 10kOhm
- Measuring range
- 0-40 kPa
- Max. overload pressure
- 200 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±1.3 % fs
-
DTK40-420Differential pressure transmitter- Sensor Interface
- 4-20 mA
- Display
- No
- Analogue output load impedance 4...20mA
- <650 Ohm (at 24 V DC)
- Measuring range
- 0-40 kPa
- Max. overload pressure
- 200 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±1.3 % fs
-
DTK100Differential pressure transmitter- Sensor Interface
- 0-10 V
- Display
- No
- Analogue output load impedance 0...10v
- > 10kOhm
- Measuring range
- 0-100 kPa
- Max. overload pressure
- 500 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±1.3 % fs
-
DTK100-420Differential pressure transmitter- Sensor Interface
- 4-20 mA
- Display
- No
- Analogue output load impedance 4...20mA
- <650 Ohm (at 24 V DC)
- Measuring range
- 0-100 kPa
- Max. overload pressure
- 500 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±1.3 % fs
-
DTK250Differential pressure transmitter- Sensor Interface
- 0-10 V
- Display
- No
- Analogue output load impedance 0...10v
- > 10kOhm
- Measuring range
- 0-250 kPa
- Max. overload pressure
- 1200 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±1.3 % fs
-
DTK250-420Differential pressure transmitter- Sensor Interface
- 0-10 V
- Display
- No
- Analogue output load impedance 4...20mA
- <650 Ohm (at 24 V DC)
- Measuring range
- 0-250 kPa
- Max. overload pressure
- 1200 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±1.3 % fs
-
DTK400Differential pressure transmitter- Sensor Interface
- 0-10 V
- Display
- No
- Analogue output load impedance 0...10v
- > 10kOhm
- Measuring range
- 0-400 kPa
- Max. overload pressure
- 1200 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±0.8 % fs
-
DTK400-420Differential pressure transmitter- Sensor Interface
- 0-10 V
- Display
- No
- Analogue output load impedance 4...20mA
- <650 Ohm (at 24 V DC)
- Measuring range
- 0-400 kPa
- Max. overload pressure
- 1200 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±0.8 % fs
-
DTK600Differential pressure transmitter- Sensor Interface
- 0-10 V
- Display
- No
- Analogue output load impedance 0...10v
- > 10kOhm
- Measuring range
- 0-600 kPa
- Max. overload pressure
- 1200 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±0.5 % fs
-
DTK600-420Differential pressure transmitter- Sensor Interface
- 0-10 V
- Display
- No
- Analogue output load impedance 4...20mA
- <650 Ohm (at 24 V DC)
- Measuring range
- 0-600 kPa
- Max. overload pressure
- 1200 kPa
- Max. system pressure
- 25 bar
- Accuracy, resolution sensor
- ±0.5 % fs
-
DTK1000Differential pressure transmitter- Sensor Interface
- 0-10 V
- Display
- No
- Analogue output load impedance 0...10v
- > 10kOhm
- Measuring range
- 0-1000 kPa
- Max. overload pressure
- 2000 kPa
- Max. system pressure
- 50 bar
- Accuracy, resolution sensor
- ±0.5 % fs
-
DTK1000-420Differential pressure transmitter- Sensor Interface
- 0-10 V
- Display
- No
- Analogue output load impedance 4...20mA
- <650 Ohm (at 24 V DC)
- Measuring range
- 0-1000 kPa
- Max. overload pressure
- 2000 kPa
- Max. system pressure
- 50 bar
- Accuracy, resolution sensor
- ±0.5 % fs
-
DTK1600Differential pressure transmitter- Sensor Interface
- 0-10 V
- Display
- No
- Analogue output load impedance 0...10v
- > 10kOhm
- Measuring range
- 0-1600 kPa
- Max. overload pressure
- 3200 kPa
- Max. system pressure
- 50 bar
- Accuracy, resolution sensor
- ±0.5 % fs
-
DTK1600-420Differential pressure transmitter- Sensor Interface
- 0-10 V
- Display
- No
- Analogue output load impedance 4...20mA
- <650 Ohm (at 24 V DC)
- Measuring range
- 0-1600 kPa
- Max. overload pressure
- 3200 kPa
- Max. system pressure
- 50 bar
- Accuracy, resolution sensor
- ±0.5 % fs
Specifications
| Power Supply | 24VAC/DC (20...28 V AC 50Hz / 18...33 V DC), 0.1 VA, 24VDC (11...33 V DC) |
|---|---|
| Protection class | IP65 |
| Ambient temperature | -15…85 °C |
| Storage temperature | -15…85 °C |
| Dimensions, external (WxHxD) | 40x79x mm |
| Media | liquids and gases |
| Cabel | Three wire cable, 1.5 m, Two wire cable, 1.5 m |
| Pressure connection | 6 mm for copper tube |
| Dynamic response time | <5 ms |
| Material, housing | Stainless steel |
| Material sensor | Ceramic material |
Software & documentation
Product sheet
Instructions
Accessories