Compact ultrasonic energy meters

Externally threaded, compact energy meters with built-in ultrasonic flow meter, intended for heating or cooling. We offer many different options, see the product sheet for more information.

Articles

(39 st)
  • SSU15-0.6-HR-M - Regin
    SSU15-0.6-HR-M
    Nominal diameter
    DN15
    Flow
    0.6 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus
    Length of flow meter
    110 mm
    Thread on meter body
    G¾"
  • SSU15-0.6-HR-MPI - Regin
    SSU15-0.6-HR-MPI
    Nominal diameter
    DN15
    Flow
    0.6 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    110 mm
    Thread on meter body
    G¾"
  • SSU15-0.6-HR-PO - Regin
    SSU15-0.6-HR-PO
    Nominal diameter
    DN15
    Flow
    0.6 m 3 /h
    Type of measurement
    Heating
    Communication interface
    Pulse output for energy
    Length of flow meter
    110 mm
    Thread on meter body
    G¾"
  • SSU15-1.5-CR-M - Regin
    SSU15-1.5-CR-M
    Nominal diameter
    DN15
    Flow
    1.5 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus
    Length of flow meter
    110 mm
    Thread on meter body
    G¾"
  • SSU15-1.5-CR-MPI - Regin
    SSU15-1.5-CR-MPI
    Nominal diameter
    DN15
    Flow
    1.5 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    110 mm
    Thread on meter body
    G¾"
  • SSU15-1.5-CR-PO - Regin
    SSU15-1.5-CR-PO
    Nominal diameter
    DN15
    Flow
    1.5 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    Pulse output for energy
    Length of flow meter
    110 mm
    Thread on meter body
    G¾"
  • SSU15-1.5-HR-M - Regin
    SSU15-1.5-HR-M
    Nominal diameter
    DN15
    Flow
    1.5 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus
    Length of flow meter
    110 mm
    Thread on meter body
    G¾"
  • SSU15-1.5-HR-MPI - Regin
    SSU15-1.5-HR-MPI
    Nominal diameter
    DN15
    Flow
    1.5 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    110 mm
    Thread on meter body
    G¾"
  • SSU15-1.5-HR-PO - Regin
    SSU15-1.5-HR-PO
    Nominal diameter
    DN15
    Flow
    1.5 m 3 /h
    Type of measurement
    Heating
    Communication interface
    Pulse output for energy
    Length of flow meter
    110 mm
    Thread on meter body
    G¾"
  • SSU20-2.5-CR-M - Regin
    SSU20-2.5-CR-M
    Nominal diameter
    DN20
    Flow
    2.5 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus
    Length of flow meter
    130 mm
    Thread on meter body
    G1"
  • SSU20-2.5-CR-MPI - Regin
    SSU20-2.5-CR-MPI
    Nominal diameter
    DN20
    Flow
    2.5 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    130 mm
    Thread on meter body
    G1"
  • SSU20-2.5-CR-PO - Regin
    SSU20-2.5-CR-PO
    Nominal diameter
    DN20
    Flow
    2.5 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    Pulse output for energy
    Length of flow meter
    130 mm
    Thread on meter body
    G1"
  • SSU20-2.5-HR-M - Regin
    SSU20-2.5-HR-M
    Nominal diameter
    DN20
    Flow
    2.5 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus
    Length of flow meter
    130 mm
    Thread on meter body
    G1"
  • SSU20-2.5-HR-MPI - Regin
    SSU20-2.5-HR-MPI
    Nominal diameter
    DN20
    Flow
    2.5 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    130 mm
    Thread on meter body
    G1"
  • SSU20-2.5-HR-PO - Regin
    SSU20-2.5-HR-PO
    Nominal diameter
    DN20
    Flow
    2.5 m 3 /h
    Type of measurement
    Heating
    Communication interface
    Pulse output for energy
    Length of flow meter
    130 mm
    Thread on meter body
    G1"
  • SSU20-3.5-CR-M - Regin
    SSU20-3.5-CR-M
    Nominal diameter
    DN20
    Flow
    3.5 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus
    Length of flow meter
    130 mm
    Thread on meter body
    G1"
  • SSU20-3.5-CR-MPI - Regin
    SSU20-3.5-CR-MPI
    Nominal diameter
    DN20
    Flow
    3.5 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    130 mm
    Thread on meter body
    G1"
  • SSU20-3.5-CR-PO - Regin
    SSU20-3.5-CR-PO
    Nominal diameter
    DN20
    Flow
    3.5 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    Pulse output for energy
    Length of flow meter
    130 mm
    Thread on meter body
    G1"
  • SSU20-3.5-HR-M - Regin
    SSU20-3.5-HR-M
    Nominal diameter
    DN20
    Flow
    3.5 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus
    Length of flow meter
    130 mm
    Thread on meter body
    G1"
  • SSU20-3.5-HR-MPI - Regin
    SSU20-3.5-HR-MPI
    Nominal diameter
    DN20
    Flow
    3.5 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    130 mm
    Thread on meter body
    G1"
  • SSU20-3.5-HR-PO - Regin
    SSU20-3.5-HR-PO
    Nominal diameter
    DN20
    Flow
    3.5 m 3 /h
    Type of measurement
    Heating
    Communication interface
    Pulse output for energy
    Length of flow meter
    130 mm
    Thread on meter body
    G1"
  • SSU25-3.5-CR-M - Regin
    SSU25-3.5-CR-M
    Nominal diameter
    DN25
    Flow
    3.5 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus
    Length of flow meter
    150 mm
    Thread on meter body
    G1¼"
  • SSU25-3.5-CR-MPI - Regin
    SSU25-3.5-CR-MPI
    Nominal diameter
    DN25
    Flow
    3.5 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    150 mm
    Thread on meter body
    G1¼"
  • SSU25-3.5-CR-PO - Regin
    SSU25-3.5-CR-PO
    Nominal diameter
    DN25
    Flow
    3.5 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    Pulse output for energy
    Length of flow meter
    150 mm
    Thread on meter body
    G1¼"
  • SSU25-3.5-HR-M - Regin
    SSU25-3.5-HR-M
    Nominal diameter
    DN25
    Flow
    3.5 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus
    Length of flow meter
    150 mm
    Thread on meter body
    G1¼"
  • SSU25-3.5-HR-MPI - Regin
    SSU25-3.5-HR-MPI
    Nominal diameter
    DN25
    Flow
    3.5 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    150 mm
    Thread on meter body
    G1¼"
  • SSU25-3.5-HR-PO - Regin
    SSU25-3.5-HR-PO
    Nominal diameter
    DN25
    Flow
    3.5 m 3 /h
    Type of measurement
    Heating
    Communication interface
    Pulse output for energy
    Length of flow meter
    150 mm
    Thread on meter body
    G1¼"
  • SSU25-6.0-CR-M - Regin
    SSU25-6.0-CR-M
    Nominal diameter
    DN25
    Flow
    6.0 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus
    Length of flow meter
    150 mm
    Thread on meter body
    G1¼"
  • SSU25-6.0-CR-MPI - Regin
    SSU25-6.0-CR-MPI
    Nominal diameter
    DN25
    Flow
    6.0 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    150 mm
    Thread on meter body
    G1¼"
  • SSU25-6.0-CR-PO - Regin
    SSU25-6.0-CR-PO
    Nominal diameter
    DN25
    Flow
    6.0 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    Pulse output for energy
    Length of flow meter
    150 mm
    Thread on meter body
    G1¼"
  • SSU25-6.0-HR-M - Regin
    SSU25-6.0-HR-M
    Nominal diameter
    DN25
    Flow
    6.0 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus
    Length of flow meter
    150 mm
    Thread on meter body
    G1¼"
  • SSU25-6.0-HR-MPI - Regin
    SSU25-6.0-HR-MPI
    Nominal diameter
    DN25
    Flow
    6.0 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    150 mm
    Thread on meter body
    G1¼"
  • SSU25-6.0-HR-PO - Regin
    SSU25-6.0-HR-PO
    Nominal diameter
    DN25
    Flow
    6.0 m 3 /h
    Type of measurement
    Heating
    Communication interface
    Pulse output for energy
    Length of flow meter
    150 mm
    Thread on meter body
    G1¼"
  • SSU40-10-CR-M - Regin
    SSU40-10-CR-M
    Nominal diameter
    DN40
    Flow
    10.0 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus
    Length of flow meter
    200 mm
    Thread on meter body
    G2"
  • SSU40-10-CR-MPI - Regin
    SSU40-10-CR-MPI
    Nominal diameter
    DN40
    Flow
    10.0 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    200 mm
    Thread on meter body
    G2"
  • SSU40-10-CR-PO - Regin
    SSU40-10-CR-PO
    Nominal diameter
    DN40
    Flow
    10.0 m 3 /h
    Type of measurement
    Cooling
    Communication interface
    Pulse output for energy
    Length of flow meter
    200 mm
    Thread on meter body
    G2"
  • SSU40-10-HR-M - Regin
    SSU40-10-HR-M
    Nominal diameter
    DN40
    Flow
    10.0 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus
    Length of flow meter
    200 mm
    Thread on meter body
    G2"
  • SSU40-10-HR-MPI - Regin
    SSU40-10-HR-MPI
    Nominal diameter
    DN40
    Flow
    10.0 m 3 /h
    Type of measurement
    Heating
    Communication interface
    M-Bus with 3 pulse inputs
    Length of flow meter
    200 mm
    Thread on meter body
    G2"
  • SSU40-10-HR-PO - Regin
    SSU40-10-HR-PO
    Nominal diameter
    DN40
    Flow
    10.0 m 3 /h
    Type of measurement
    Heating
    Communication interface
    Pulse output for energy
    Length of flow meter
    200 mm
    Thread on meter body
    G2"
Specifications for Compact ultrasonic energy meters
Power supply Exchangeable 3 V lithium battery, estimated lifetime 10 years. 24 V and 230 V power packs available as accessory.
Temperature range 0…50 °C, 15…90°C
Temperature difference range, heating 3…100 K
Temperature difference range, cooling -3…-50 K
Temperature resolution 0.01°C
Ambient temperature 5…55°C
Storage temperature 1…60°C
Ambient humidity Max. 95% RH
Protection class IP65
Calculation of heat from K ΔΘ > 0.05K
Calculation of cooling from K ΔΘ < -0.05K
Measurement cycle, flow 2 s
Measurement cycle, temperature 2…60 s
Measurement cycle, temperature (using 230 V power pack) 2 s
Data storage Non-volatile memory
Interfaces M-Bus, pulse output or M-Bus with 3 pulse inputs
Reading dates 15 monthly and semi monthly values via display, 24 monthly and semimonthly values via optical interface or M-Bus. Annual billing date selectable.
Display LCD, 8 digits + special characters
Display units MWh, kW, GJ, m 3 , m 3 /h (kWh, GJ, l , l/h, MW, MMBTU, Gcal), 3 decimal places. The unit for energy consumption can only be set while the energy consumption is ≤ 10 kWh.
Mechanical class Class M1 (MID: 31.03.2004 annex I)
EMC Class E1 (MID: 31.03.2004 annex I)
Dimensions, calculator (WxHxD) 110 x 75 x 34.5mm
Cable length (measuring unit) 85 cm
Cable length 1.5m
Sensor element PT1000, DIN IEC 60751
Diameter, sensor 5mm
Installation Direct (see the accessories section) or indirect in a temperature sensor pocket per EN1434
Temperature sensor requirements, heat meter EU (MID) identification on the temperature sensors
Temperature sensor requirements, cooling meter National German approval as a temperature sensor for cooling meters. Requirements in other countries may be different.
Connection Threaded according to ISO 228/1
Pressure rating PN16
Media Water
Mounting position Horizontal or vertical
Point of installation Return flow (if forward flow installation is needed, the installation position can be changed with the main button)
Measuring principle Ultrasonic; time-of-flight
Dynamic range q i /q p 1:100 (1:50 for q p 0.6)
Accuracy according to MID Class 2
Recommended minimum system pressure 1 bar
VSR-1/2

Brass threaded fitting with coupling ring and gasket

VSR-3/4

Brass threaded fitting with coupling ring and gasket

VSR-1

Brass threaded fitting with coupling ring and gasket

VSR-1 1/2

Brass threaded fitting with coupling ring and gasket

KH-3/4

Ball valve with coupling ring and gasket

KH-1

Ball valve with coupling ring and gasket

KH-1 1/4

Ball valve with coupling ring and gasket

KH-2

Ball valve with coupling ring and gasket

KH-S-3/4

Ball valve with installation point for a temperature sensor (sockets M10x1)

KH-S-1

Ball valve with installation point for a temperature sensor (sockets M10x1)

KH-S-1 1/4

Ball valve with installation point for a temperature sensor (sockets M10x1)

KH-S-2

Ball valve with installation point for a temperature sensor (sockets M10x1)

VAD-1/2

Supply flow adapter with gasket, for direct mounting of a temperature sensor in a T-piece

VAD-3/8

Supply flow adapter with gasket, for direct mounting of a temperature sensor in a T-piece

PS-110-3/4

Threaded fit

PS-130-1

Threaded fit

OPTO-CABLE-USB

Optocoupler with USB interface

OPTO-TOOL

Software device monitor

POWERPACK-EM

230 V power pack

POWERPACK-EM-24

24 V AC power pack

BATTERY-EM

Battery for SSU and SSCU