Woltmann type combined energy meter
This product is discontinued
Flanged Woltmann flow meters for large nominal flows, intended for flow measurements in large plants, such as those found in district heating systems.We offer many different options, see the WSTH/WPTH product sheet for more information.Note: Non-stock item.
Navigate on this page
Articles
(126 st)-
WSTH100-60-CR-M
- Nominal diameter
- DN100
- Flow
- 60 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
-
WSTH100-60-HCR-M
- Nominal diameter
- DN100
- Flow
- 60 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus
-
WSTH100-60-HCR-PO
- Nominal diameter
- DN100
- Flow
- 60 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- Pulse output for energy
-
WPTH50-15-CR-M
- Nominal diameter
- DN50
- Flow
- 15 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
-
WPTH50-15-CR-MPI
- Nominal diameter
- DN50
- Flow
- 15 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH50-15-CR-PO
- Nominal diameter
- DN50
- Flow
- 15 m3/h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
-
WPTH50-15-HCR-M
- Nominal diameter
- DN50
- Flow
- 15 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus
-
WPTH50-15-HCR-MPI
- Nominal diameter
- DN50
- Flow
- 15 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH50-15-HCR-PO
- Nominal diameter
- DN50
- Flow
- 15 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- Pulse output for energy
-
WPTH50-15-HR-M
- Nominal diameter
- DN50
- Flow
- 15 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus
-
WPTH50-15-HR-MPI
- Nominal diameter
- DN50
- Flow
- 15 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH50-15-HR-PO
- Nominal diameter
- DN50
- Flow
- 15 m3/h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
-
WPTH65-25-CR-M
- Nominal diameter
- DN65
- Flow
- 25 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
-
WPTH65-25-CR-MPI
- Nominal diameter
- DN65
- Flow
- 25 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH65-25-CR-PO
- Nominal diameter
- DN65
- Flow
- 25 m3/h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
-
WPTH65-25-HCR-M
- Nominal diameter
- DN65
- Flow
- 25 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus
-
WPTH65-25-HCR-MPI
- Nominal diameter
- DN65
- Flow
- 25 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH65-25-HCR-PO
- Nominal diameter
- DN65
- Flow
- 25 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- Pulse output for energy
-
WPTH65-25-HR-M
- Nominal diameter
- DN65
- Flow
- 25 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus
-
WPTH65-25-HR-MPI
- Nominal diameter
- DN65
- Flow
- 25 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH65-25-HR-PO
- Nominal diameter
- DN65
- Flow
- 25 m3/h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
-
WPTH80-32-CR-M
- Nominal diameter
- DN80
- Flow
- 32 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
-
WPTH80-32-CR-MPI
- Nominal diameter
- DN80
- Flow
- 32 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH80-32-CR-PO
- Nominal diameter
- DN80
- Flow
- 32 m3/h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
-
WPTH80-32-HCR-M
- Nominal diameter
- DN80
- Flow
- 32 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus
-
WPTH80-32-HCR-MPI
- Nominal diameter
- DN80
- Flow
- 32 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH80-32-HCR-PO
- Nominal diameter
- DN80
- Flow
- 32 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- Pulse output for energy
-
WPTH80-32-HR-M
- Nominal diameter
- DN80
- Flow
- 32 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus
-
WPTH80-32-HR-MPI
- Nominal diameter
- DN80
- Flow
- 32 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH80-32-HR-PO
- Nominal diameter
- DN80
- Flow
- 32 m3/h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
-
WPTH100-60-CR-M
- Nominal diameter
- DN100
- Flow
- 60 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
-
WPTH100-60-CR-MPI
- Nominal diameter
- DN100
- Flow
- 60 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH100-60-CR-PO
- Nominal diameter
- DN100
- Flow
- 60 m3/h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
-
WPTH100-60-HCR-M
- Nominal diameter
- DN100
- Flow
- 60 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus
-
WPTH100-60-HCR-MPI
- Nominal diameter
- DN100
- Flow
- 60 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH100-60-HCR-PO
- Nominal diameter
- DN100
- Flow
- 60 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- Pulse output for energy
-
WPTH100-60-HR-M
- Nominal diameter
- DN100
- Flow
- 60 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus
-
WPTH100-60-HR-MPI
- Nominal diameter
- DN100
- Flow
- 60 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH100-60-HR-PO
- Nominal diameter
- DN100
- Flow
- 60 m3/h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
-
WPTH125-100-CR-M
- Nominal diameter
- DN125
- Flow
- 100 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
-
WPTH125-100-CR-MPI
- Nominal diameter
- DN125
- Flow
- 100 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH125-100-CR-PO
- Nominal diameter
- DN125
- Flow
- 100 m3/h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
-
WPTH125-100-HCR-M
- Nominal diameter
- DN125
- Flow
- 100 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus
-
WPTH125-100-HCR-MPI
- Nominal diameter
- DN125
- Flow
- 100 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH125-100-HCR-PO
- Nominal diameter
- DN125
- Flow
- 100 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- Pulse output for energy
-
WPTH125-100-HR-M
- Nominal diameter
- DN125
- Flow
- 100 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus
-
WPTH125-100-HR-MPI
- Nominal diameter
- DN125
- Flow
- 100 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH125-100-HR-PO
- Nominal diameter
- DN125
- Flow
- 100 m3/h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
-
WPTH150-200-CR-M
- Nominal diameter
- DN150
- Flow
- 200 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
-
WPTH150-200-CR-MPI
- Nominal diameter
- DN150
- Flow
- 200 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH150-200-CR-PO
- Nominal diameter
- DN150
- Flow
- 200 m3/h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
-
WPTH150-200-HCR-M
- Nominal diameter
- DN150
- Flow
- 200 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus
-
WPTH150-200-HCR-MPI
- Nominal diameter
- DN150
- Flow
- 200 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH150-200-HCR-PO
- Nominal diameter
- DN150
- Flow
- 200 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- Pulse output for energy
-
WPTH150-200-HR-M
- Nominal diameter
- DN150
- Flow
- 200 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus
-
WPTH150-200-HR-MPI
- Nominal diameter
- DN150
- Flow
- 200 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH150-200-HR-PO
- Nominal diameter
- DN150
- Flow
- 200 m3/h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
-
WPTH200-250-CR-MPI
- Nominal diameter
- DN200
- Flow
- 250 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH200-250-CR-PO
- Nominal diameter
- DN200
- Flow
- 250 m3/h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
-
WPTH200-250-HCR-M
- Nominal diameter
- DN200
- Flow
- 250 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus
-
WPTH200-250-HCR-MPI
- Nominal diameter
- DN200
- Flow
- 250 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH200-250-HCR-PO
- Nominal diameter
- DN200
- Flow
- 250 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- Pulse output for energy
-
WPTH200-250-HR-M
- Nominal diameter
- DN200
- Flow
- 250 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus
-
WPTH200-250-HR-MPI
- Nominal diameter
- DN200
- Flow
- 250 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH200-250-HR-PO
- Nominal diameter
- DN200
- Flow
- 250 m3/h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
-
WPTH250-400-CR-M
- Nominal diameter
- DN250
- Flow
- 400 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
-
WPTH250-400-CR-MPI
- Nominal diameter
- DN250
- Flow
- 400 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH250-400-CR-PO
- Nominal diameter
- DN250
- Flow
- 400 m3/h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
-
WPTH250-400-HCR-M
- Nominal diameter
- DN250
- Flow
- 400 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus
-
WPTH250-400-HCR-MPI
- Nominal diameter
- DN250
- Flow
- 400 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH250-400-HCR-PO
- Nominal diameter
- DN250
- Flow
- 400 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- Pulse output for energy
-
WPTH250-400-HR-M
- Nominal diameter
- DN250
- Flow
- 400 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus
-
WPTH250-400-HR-MPI
- Nominal diameter
- DN250
- Flow
- 400 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH250-400-HR-PO
- Nominal diameter
- DN250
- Flow
- 400 m3/h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
-
WPTH300-600-CR-M
- Nominal diameter
- DN300
- Flow
- 600 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
-
WPTH300-600-CR-MPI
- Nominal diameter
- DN300
- Flow
- 600 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH300-600-CR-PO
- Nominal diameter
- DN300
- Flow
- 600 m3/h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
-
WPTH300-600-HCR-M
- Nominal diameter
- DN300
- Flow
- 600 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus
-
WPTH300-600-HCR-MPI
- Nominal diameter
- DN300
- Flow
- 600 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH300-600-HCR-PO
- Nominal diameter
- DN300
- Flow
- 600 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- Pulse output for energy
-
WPTH300-600-HR-M
- Nominal diameter
- DN300
- Flow
- 600 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus
-
WPTH300-600-HR-MPI
- Nominal diameter
- DN300
- Flow
- 600 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
-
WPTH300-600-HR-PO
- Nominal diameter
- DN300
- Flow
- 600 m3/h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
-
WPTH200-250-CR-M
- Nominal diameter
- DN200
- Flow
- 250 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
-
WSTH50-15-CR-M
- Nominal diameter
- DN50
- Flow
- 15 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
-
WSTH50-15-CR-MPI
- Nominal diameter
- DN50
- Flow
- 15 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
-
WSTH50-15-CR-PO
- Nominal diameter
- DN50
- Flow
- 15 m3/h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
-
WSTH50-15-HCR-M
- Nominal diameter
- DN50
- Flow
- 15 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus
-
WSTH50-15-HCR-MPI
- Nominal diameter
- DN50
- Flow
- 15 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus with 3 pulse inputs
-
WSTH50-15-HCR-PO
- Nominal diameter
- DN50
- Flow
- 15 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- Pulse output for energy
-
WSTH50-15-HR-M
- Nominal diameter
- DN50
- Flow
- 15 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus
-
WSTH50-15-HR-MPI
- Nominal diameter
- DN50
- Flow
- 15 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
-
WSTH50-15-HR-PO
- Nominal diameter
- DN50
- Flow
- 15 m3/h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
-
WSTH65-25-CR-M
- Nominal diameter
- DN65
- Flow
- 25 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
-
WSTH65-25-CR-MPI
- Nominal diameter
- DN65
- Flow
- 25 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
-
WSTH65-25-CR-PO
- Nominal diameter
- DN65
- Flow
- 25 m3/h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
-
WSTH65-25-HCR-M
- Nominal diameter
- DN65
- Flow
- 25 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus
-
WSTH65-25-HCR-MPI
- Nominal diameter
- DN65
- Flow
- 25 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus with 3 pulse inputs
-
WSTH65-25-HCR-PO
- Nominal diameter
- DN65
- Flow
- 25 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- Pulse output for energy
-
WSTH65-25-HR-M
- Nominal diameter
- DN65
- Flow
- 25 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus
-
WSTH65-25-HR-MPI
- Nominal diameter
- DN65
- Flow
- 25 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
-
WSTH65-25-HR-PO
- Nominal diameter
- DN65
- Flow
- 25 m3/h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
-
WSTH80-40-CR-M
- Nominal diameter
- DN80
- Flow
- 40 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
-
WSTH80-40-CR-MPI
- Nominal diameter
- DN80
- Flow
- 40 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
-
WSTH80-40-CR-PO
- Nominal diameter
- DN80
- Flow
- 40 m3/h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
-
WSTH80-40-HCR-M
- Nominal diameter
- DN80
- Flow
- 40 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus
-
WSTH80-40-HCR-MPI
- Nominal diameter
- DN80
- Flow
- 40 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus with 3 pulse inputs
-
WSTH80-40-HCR-PO
- Nominal diameter
- DN80
- Flow
- 40 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- Pulse output for energy
-
WSTH80-40-HR-M
- Nominal diameter
- DN80
- Flow
- 40 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus
-
WSTH80-40-HR-MPI
- Nominal diameter
- DN80
- Flow
- 40 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
-
WSTH80-40-HR-PO
- Nominal diameter
- DN80
- Flow
- 40 m3/h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
-
WSTH100-60-CR-MPI
- Nominal diameter
- DN100
- Flow
- 60 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
-
WSTH100-60-CR-PO
- Nominal diameter
- DN100
- Flow
- 60 m3/h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
-
WSTH100-60-HCR-MPI
- Nominal diameter
- DN100
- Flow
- 60 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus with 3 pulse inputs
-
WSTH100-60-HR-M
- Nominal diameter
- DN100
- Flow
- 60 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus
-
WSTH100-60-HR-MPI
- Nominal diameter
- DN100
- Flow
- 60 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
-
WSTH100-60-HR-PO
- Nominal diameter
- DN100
- Flow
- 60 m3/h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
-
WSTH150-150-CR-M
- Nominal diameter
- DN150
- Flow
- 150 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus
-
WSTH150-150-CR-MPI
- Nominal diameter
- DN150
- Flow
- 150 m3/h
- Type of measurement
- Cooling
- Communication interface
- M-Bus with 3 pulse inputs
-
WSTH150-150-CR-PO
- Nominal diameter
- DN150
- Flow
- 150 m3/h
- Type of measurement
- Cooling
- Communication interface
- Pulse output for energy
-
WSTH150-150-HCR-M
- Nominal diameter
- DN150
- Flow
- 150 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus
-
WSTH150-150-HCR-MPI
- Nominal diameter
- DN150
- Flow
- 150 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- M-Bus with 3 pulse inputs
-
WSTH150-150-HCR-PO
- Nominal diameter
- DN150
- Flow
- 150 m3/h
- Type of measurement
- Heating and cooling in combination
- Communication interface
- Pulse output for energy
-
WSTH150-150-HR-M
- Nominal diameter
- DN150
- Flow
- 150 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus
-
WSTH150-150-HR-MPI
- Nominal diameter
- DN150
- Flow
- 150 m3/h
- Type of measurement
- Heating
- Communication interface
- M-Bus with 3 pulse inputs
-
WSTH150-150-HR-PO
- Nominal diameter
- DN150
- Flow
- 150 m3/h
- Type of measurement
- Heating
- Communication interface
- Pulse output for energy
Specifications
Power supply | Replaceable 3 V lithium AA battery, min. 6 + 1 years |
---|---|
Temperature range | 1...150°C |
Temperature resolution | 0.01°C |
Ambient temperature | 5...55°C |
Storage temperature | -20…+60°C |
Protection class | IP65 |
Connection | Flanged according to EN 1092-2 |
Pressure rating | PN16 |
Media | Water |
Mounting position | WSTH horizontal only, WPTH horizontal or vertical |
Cable length | 3m |
Sensor element | PT500; separately approved type as per EN60751, unshielded |
Diameter, sensor | 6mm |